1. Copper Pipes
Flexible copper pipes supplied in coils. Widely used in air conditioning, refrigeration systems, and heat exchange applications where long continuous lengths without joints are required. High ductility and corrosion resistance make them ideal for confined spaces.
Applications
Air conditioning
Refrigeration
Heat exchangers
Available outer diameters (mm)
44.76566.35
77.47.9489.4
9.52101212.713
13.413.81414.615
15.881616.516.617.6
1819.0519.82022
22.232525.42828.57
2930313334.93
353841.2842
Available wall thicknesses (mm)
0.250.280.30.350.37
0.40.410.450.50.52
0.550.560.60.610.65
0.70.720.740.750.76
0.80.810.830.850.86
0.890.90.910.940.95
0.961.01.071.121.14
1.21.271.31.41.5
1.522.0
Non-standard sizes available on request. Minimum order quantity varies by size.
2. Copper Pancake Coils
Flat copper tube coils for residential and commercial air conditioning systems and refrigeration equipment. Easy to transport, cut, and install; suitable for soldering and other connection methods.
Applications
Residential HVAC
Commercial HVAC
Refrigeration equipment
Available outer diameters (mm)
44.76566.35
77.47.9489.4
9.52101212.713
13.413.81414.615
15.881616.516.617.6
1819.05
Available wall thicknesses (mm)
0.250.280.30.350.37
0.40.410.450.50.52
0.550.560.60.610.65
0.70.720.740.750.76
0.80.830.850.860.89
0.90.940.950.961.0
1.21.31.52.0
Non-standard sizes available on request.
3. Copper LWC Coils
Flexible LWC (Large Weight Coil) copper tubes supplied in large coils. Used in air conditioning systems, heat pumps, refrigeration, and medical equipment. High ductility and dimensional accuracy make them ideal for automated production lines.
Applications
Air conditioning
Heat pumps
Refrigeration
Medical equipment
Automated production lines
Available outer diameters (mm)
44.76566.35
77.47.9489.4
9.52101212.713
13.413.81414.615
15.881616.516.617.6
1819.0519.82022
22.23
Available wall thicknesses (mm)
0.250.280.30.350.37
0.40.410.450.50.52
0.550.560.60.610.65
0.70.720.740.750.76
0.80.810.830.850.86
0.890.90.940.950.96
1.01.141.21.31.5
2.0
Non-standard sizes available on request.
4. Copper Fittings
Standard EN 1254-1, GOST, DIN
Material Cu-DHP Copper 99.9%
Connection Capillary soldering
Capillary-soldered copper fittings used across water, gas, heating, HVAC, plumbing and industrial systems. All fittings share three core properties: high geometric precision (strict DIN geometry), leak-tightness (ideal for soldering) and versatility across media.
Applications
Water
Gas
Heating
HVAC
Plumbing
Industrial systems
4.1 — 45° Elbow · Article 5001A
Double-socket copper elbow for smooth 45° directional change. Minimal hydraulic resistance.
| Metric (mm) | Inch |
| 22 | 7/8 |
| 28 | 1 1/8 |
| 35 | 1 3/8 |
| 42 | 1 5/8 |
4.2 — 90° Elbow · Article 5090A
Double-socket copper elbow for smooth 90° directional change. Minimal hydraulic resistance.
| Metric (mm) | Inch |
| 8 | 5/16 |
| 10 | 3/8 |
| 12 | 1/2 |
| 15 | — |
| 16 | 5/8 |
| 18 | — |
| 19 | 3/4 |
| 22 | 7/8 |
| 25 | 1 |
| 28 | 1 1/8 |
| 35 | 1 3/8 |
| 42 | 1 5/8 |
4.3 — 90° Long-Radius Elbow · Article 5002A
Double-socket copper elbow with extended radius for improved flow characteristics. Minimal hydraulic resistance.
| Metric (mm) | Inch |
| 8 | 5/16 |
| 10 | 3/8 |
| 12 | 1/2 |
| 15 | — |
| 16 | 5/8 |
| 18 | 3/4 |
| 19 | 3/4 |
| 22 | 7/8 |
| 25 | 1 |
| 28 | 1 1/8 |
| 35 | 1 3/8 |
| 42 | 1 5/8 |
4.4 — Coupling · Article 5270
Double-socket copper coupling for joining two pipes of the same diameter. Leak-proof — for plumbing, HVAC and industrial systems.
| Metric (mm) | Inch |
| 8 | — |
| 10 | 3/8 |
| 12 | 1/2 |
| 15 | — |
| 18 | 3/4 |
| 22 | 7/8 |
| 25 | 1 |
| 28 | 1 1/8 |
| 35 | 1 3/8 |
| 42 | 1 5/8 |
4.5 — Reducer Coupling · Article 5240
Copper reducer coupling for connecting pipes of different diameters. Secure transition with excellent sealing.
Available size pairs (large × small, mm)
10×812×812×1015×1015×12
18×1218×1522×1022×1222×15
22×1828×1228×1528×1828×22
35×1835×2235×2842×1842×22
42×2842×35
4.6 — Tee · Article 5130
Copper tee fitting for creating a branch from the main pipeline. Uniform flow distribution and high durability.
| Metric (mm) | Inch |
| 8 | 5/16 |
| 10 | 3/8 |
| 12 | 1/2 |
| 15 | — |
| 16 | 5/8 |
| 18 | — |
| 19 | 3/4 |
| 22 | 3/4 |
| 25 | 7/8 |
| 28 | 1 |
| 35 | 1 1/8 |
| 42 | 1 3/8 |
5. Insulated Copper Pipes
Copper pipes with durable thermal insulation. A modern solution for air conditioning, cooling and heating systems — minimal heat loss, protection against condensation and a long service life.
Applications
Air conditioning
Cooling systems
Heating systems
Available outer diameters (mm)
6.359.5212.715.8819.05
Available wall thicknesses (mm)
0.70.750.80.810.91.0
Non-standard sizes available on request.
6. Copper Solder
Copper solders for creating strong and durable joints. Excellent flow properties, resistance to high temperatures and aggressive environments. Precise composition with strict quality control.
Applications
Air conditioning systems
Heat exchangers
Plumbing
Medical equipment
- Technical specs
- GOST 617-2006, EN 1057, ASTM B88
- Material condition
- Soft (R220), Half-Hard (R250), Hard (R290)
7. Copper Cathodes
High-grade copper cathodes meeting international purity standards (99.99% Cu). Used as raw material for the full production cycle — from melting to finished pipes, fittings and solders. Also available as a stand-alone product.
- Purity
- 99.99% Cu
- Role
- Raw material — also available as a finished product
- Standards
- International purity standards
8. Cable Products
Power cables with plastic insulation for transmission and distribution of electrical energy in stationary installations.
- Voltage rating
- Up to 3–6 kV
- Nominal AC voltages
- 0.66 kV, 1 kV, 3 kV
- Frequency
- 50 Hz
- Standards
- GOST
9. Medical Copper Pipes
Manufactured with advanced technologies in compliance with the European standard EN 13348. Compatible with equipment produced under the Medical Device Directive 93/42/EEC. The result of extensive research and testing.
Applications
Medical gas systems
Hospital infrastructure
- Standard
- EN 13348
- Directive compliance
- Medical Device Directive 93/42/EEC
- Alloy
- M1, M1r, M2 (Cu-DHP per EN 1057)
- Outer diameter
- 6 mm – 108 mm
- Wall thickness
- 0.5 mm – 2.5 mm
- Tensile strength
- 290 MPa (hard)
- Elongation
- min 3% (hard) / min 40% (soft)